Command INIT starts communication between processor and software. Optionally a password can be defined in the device configuration, which has to be indicated. If no password is defined, the device is always set to the IDLE state. (added 1.8) The password has to be compared with the password stored on the BP. (/) Change in state from OFFLINE to the state, that was last active. telegram INIT password response positive, if the BP was in the state OFFLINE and if a valid password has been sent. Example > INIT 1234 < +OK