Ответ:
(«Телесистемы»: Конференция «Микроконтроллеры и их применение»)

миниатюрный аудио-видеорекордер mAVR

Отправлено parashutist 03 ноября 2006 г. 01:54
В ответ на: Повтори, добавив ключ -! отправлено =AVR= 03 ноября 2006 г. 01:24


avreal/WIN32 - AVR controllers LPT programmer by Redchuk Alexandr
v1.25rev4 (Mar 24 2006 08:54:51) http://www.ln.com.ua/~real/avreal
bug-reports, suggestions and so on mail to avreal@real.kiev.ua

Command:
-p1 -as +mega16 -o0 -! -f -e -v -%
% LPT base port 0x378
% assume that LPT data writes not faster then 1uS
% Atmel adapter for STK*00 found
% STK mode
% osc = 0kHz -> XTAL will be generated
% with SCK low 2 periods, high 2 periods
% Reset
% PgmOn reply 0x00AC5300
% Synchronised after 1 try
% GetID reply 0x00300000
% GetID reply 0x00300001
% GetID reply 0x00300002
% Read ID: 0x000102
Device connected, but not recognised, ID: 0x000102 (looks as protected)
% ReadLock command 0x58000000
% ReadLock reply 0x00580000
Chip locked - reading and programming disabled
% ReadOsccal command 0x38000000
% ReadOsccal reply 0x00380000
% ReadOsccal command 0x38000100
% ReadOsccal reply 0x00380001
% ReadOsccal command 0x38000200
% ReadOsccal reply 0x00380002
% ReadOsccal command 0x38000300
% ReadOsccal reply 0x00380003
% Erase reply 0x00AC8000
Device erased
% Reset
% PgmOn reply 0x00AC5300
% Synchronised after 1 try
% GetID reply 0x00300000
% GetID reply 0x00300001
% GetID reply 0x00300002
% Read ID: 0x000102
Device connected, but not recognised, ID: 0x000102 (looks as protected)
% ReadLock command 0x58000000
% ReadLock reply 0x00580000
Device type forced to MEGA16
% ReadFuses command 0x50000000
% ReadFuses reply 0x00500000
% ReadFuses command 0x58000000
% ReadFuses reply 0x00580000
% ReadFuses command 0x58080000
% ReadFuses reply 0x00580800
Fuses
OSCCAL = 00, 01, 02, 03
BODLEVEL = 0
BODEN = 0
SUT = 0
CKSEL = 0
BLB1 = 0
BLB0 = 0
OCDEN = 0
JTAGEN = 0
CKOPT = 0
EESAVE = 0
BOOTSZ = 0
BOOTRST = 0
Verifying fuses
% ReadFuses command 0x50000000
% ReadFuses reply 0x00500000
% ReadFuses command 0x58000000
% ReadFuses reply 0x00580000
% ReadFuses command 0x58080000
% ReadFuses reply 0x00580800
passed
Reset pin released
Adapter disabled

Составить ответ  |||  Конференция  |||  Архив

Ответы


Отправка ответа
Имя (обязательно): 
Пароль: 
E-mail: 

Тема (обязательно):
Сообщение:

Ссылка на URL: 
Название ссылки: 
URL изображения: 


Rambler's Top100 Рейтинг@Mail.ru
Перейти к списку ответов  |||  Конференция  |||  Архив  |||  Главная страница  |||  Содержание